NCC 2025 webinar series: Access, egress and safe movement
Watch on YouTubeVideo summary
The NCC 2025 introduces several significant concessions aimed at clarifying requirements for small ramps and defining specific ramp types such as curb, step, and threshold ramps to prevent unnecessary handrail mandates where they are not practically needed. A key distinction is made between these smaller ramps and larger ones that require strict adherence to slip resistance standards; while minor thresholds like those found in loading docks or at building entrances may be exempt from certain provisions due to their size, curb ramps remain subject to slip resistance requirements because of their critical safety function. The new definitions adopted for NCC 2025 are intentionally kept high-level and dictionary-style rather than incorporating detailed regulatory dimensions directly into the definition text, ensuring that valid existing installations like steeper step ramps in loading docks do not become non-compliant simply due to a change in wording.
Another major update involves mandatory wayfinding signage under new provision D3D31, which is designed primarily to assist emergency services but also benefits building occupants during egress. This requirement applies to buildings with an effective height of 12 meters or more than three stories below ground level and necessitates specific signs for stairway identification, floor levels, and sole occupancy units in Class Two and Three buildings like apartments and motels. Additionally, the rules regarding exit widths have been refined to account for fire compartments; previously, exit width calculations were based on total story occupancy regardless of internal walls with Fire Resistance Levels (FRL), but NCC 2025 now mandates that exits must be sufficient for each compartment's specific occupant load, effectively making it mandatory what was often considered good practice in designs involving horizontal exits.
Significant changes also affect threshold design and re-entry requirements from fire-isolated stairways to address accessibility and safety concerns more broadly. The previous allowances for steps or ramps within door thresholds have been removed for patient care areas and residential use zones, requiring level access even where occupants may be vulnerable, while a new concession permits small steps in plant rooms to accommodate equipment leaks without compromising space efficiency. Furthermore, the restrictions on locking fire-isolated exit doors have expanded; previously limited to specific healthcare and high-rise scenarios, NCC 2025 now requires re-entry capabilities for all Class Nine buildings including schools, as well as apartments, hotels, shopping centers, and car parks, ensuring that people can easily return from a stairway to the floor they entered without having to navigate complex evacuation routes unnecessarily.
Finally, the housing provisions have been updated regarding stairs serving non-habitable rooms like attics and store rooms, shifting away from referencing external standards for inspection personnel access. The code now explicitly allows Class 10b structures such as radio masts and communication towers to utilize AS 1657 for their stairways, ladders, platforms, and walkways without needing a special performance solution or normal residential stairs. This change consolidates the requirements within the NCC itself while broadening the scope beyond just inspection access to include general use in specialized structures, thereby providing clearer guidance that avoids sending builders back to separate standards like AS 1657 for every minor stairway installation.
Read the full video transcript
Thanks Adrian. First up is a new
concession we've introduced for NCC
2025.
This concession applies to volume one
and the housing provisions.
The best way to describe the concession
is to start by asking your question.
Does this ramp in front of a bank
require a handrail?
I know there's a lot of things wrong
with it. It's an older building, so it
might predate current requirements.
But does it need a handrail?
I'm sure most of you are thinking, of
course not. The ramp is so small that
you don't need a handrail to use it.
But what does the NCC say?
Here's D3 D22.
It asks for handrails to ramps in
subclause 1A.
And although it's a small ramp, it's
still a ramp. So, strictly speaking,
it could be said that this simple ramp
requires a handrail.
It was never intended that small ramps
like step ramps, threshold ramps, and
curb ramps would need handrails.
So, we've clarified this for NCC 2025.
Eagle-eyed viewers will have noticed
something else new in this slide. It's
to do with the terms step ramp,
threshold ramp, and curb ramp.
To achieve clarity for these
concessions, we've introduced defined
terms for these three types of ramp.
We've used these terms in the NCC for
many years now, but haven't defined them
until NCC 2025.
And here they are.
Curb ramp, a ramp at the curb.
Step ramp, a ramp that isn't a curb ramp
that's not taller than 190 mm, the
maximum height of a standard riser.
And threshold ramp, a ramp that's within
or at the threshold.
Typically, these are very small ramps.
In AS 1428.1, the standard for access
for people with a disability,
a threshold ramp can't be taller than 35
mm.
Some of you might be wondering, why we
use the definitions in AS 1428 Part 1?
Good question.
The reason that we didn't use those
definitions is because they're too
detailed.
You see, definitions in the NCC or
standard aren't just a dictionary.
Very often, definitions contain
requirements.
And AS 1428 Part 1 regulates the
dimensions of these ramps through the
definition itself.
For example, a step ramp per the
definition of AS 1428 Part 1
can't be steeper than 1 in 10.
That's not a dictionary entry, that's a
rule.
You see, if you put a step ramp in your
house or your loading dock, it can be 1
in 8.
So, we've kept our definitions more
high-level or dictionary style
because if we used the definition in AS
1428 Part 1, we would suddenly stop
allowing 1 in 8 ramps where they are
validly installed.
The NCC asks for landings and slip
resistance for ramps and usually also
for handrails.
This table shows where we've introduced
concessions to clarify that small ramps
are exempt.
Notice that we've kept slip resistance
for curb ramps and step ramps.
That's because these ramps are
significant enough to require slip
resistance.
And keep in mind that there are multiple
provisions that apply to ramps. So, even
if one of these provisions contain a
concession,
it could be the case that another
provision requires the feature.
For example, that ramp I showed on the
other slide,
even though it's at a threshold, it's
part of an accessway, so Part D4
requires a slip-resistant finish.
Next change in the NCC is a new
provision, D3 D31, requiring wayfinding
signage in buildings.
Predominantly for emergency agencies
like the fire brigade.
But most of these signs can also be
useful for occupants using exits.
Because this is new, D3 D31 comes with a
new performance requirement, D1 P10,
which requires signage to assist egress
and emergency service activities.
D3 D31 requires stairway identification
signs,
floor level identification signs, and
sole unit or SAU indicator signs.
The requirement for these signs kicks in
when you have an effective height of 12
m or more
or more than three stories below ground.
In these buildings, stairway
identification signs are needed. These
are installed on the outside of required
exit stairways.
And if the stairway doesn't serve all
the levels in the building, the signs
also need to indicate what levels the
stairs serves.
This is useful information for fire
brigades. For example, stairway here
isn't useful if they are attending a
fire in the basement.
Next are the floor level identification
signs.
These are required both inside the exit
stairway and outside the exit stairway
where you leave the stairway.
These signs need to identify what level
you're on.
And if the building is class two or
class three, like an apartment building
or a motel,
then sole occupancy unit indicator signs
are needed.
These are placed below the level signs
and show the direction to the sole
occupancy units on that floor.
Again, useful for emergency personnel if
they are in a hurry to get to a
particular unit.
This next change is in D2 D8, width of
exits.
To explain the change, I'll start with
this hypothetical floor plate.
Let's say this single story building has
an occupancy of 350 people.
Anything over 100 occupants, you have to
start thinking about D2D8 exit widths.
So, let's do that now.
For occupancies over 200, D2D8 sub
clause 3 gives you 2 m for your first
200 occupants.
And as long as there's no change in
floor level, you then need another 500
mm for every 75 occupants.
So, in this case, we need another meter
for the remaining 150 occupants.
That's a required exit width of 3 m
total.
When it comes to the exit doorways, D2D9
lets us discount each doorway 250 mm.
So, three 750 mm wide exit doors meets
our needs for this story.
But, what happens when we put in a wall
with an FRL and these horizontal exits?
The occupancy of the story is still 350.
But, let's put 75 people in compartment
A and 275 people in compartment B.
Do we still have enough exits?
At a glance, it looks like B is a bit
light. There's only two exits, which is
only enough for 200 people.
But, it's okay under the current NCC.
Because D2D8 only applies to a story, a
mezzanine, or an open spectator stand.
Nothing about fire compartments.
So, that's changed for NCC 2025.
We've added the new text down here. So,
B now needs 2.5 m of exits. Easily met
by an additional exit door.
I'm sure many have been designing this
way anyway. It's good practice.
But, for NCC 2025, it becomes mandatory.
This next change is in D3D16 thresholds.
This is the provision that says you
know, allowed to have a step or ramp
within a door width of the threshold.
Except for many years it's had these
four concessions.
Firstly, patient care areas for class 9A
buildings.
You can have a 25 mm step or ramp.
Secondly, class 9C residential care
buildings. You can have a 25 mm ramp in
the resident use areas. Like this one
pictured here.
Thirdly, external doors to road or open
space. We need to provide access for
people with a disability.
You can ramp these in accordance with AS
1428 part one, so long as that standard
doesn't require a landing for the door.
And fourthly, all other external doors.
So, where you don't need to provide
access for people with a disability, you
can have a step of up to 190 mm.
There is a fifth category not listed in
D3D16.
D3D2 application of part means that that
this clause doesn't apply within sole
occupancy units of class two and three
buildings, and in class four parts of
buildings.
Now, I've often wondered about these
first two. Because in an office building
where most occupants are able-bodied,
there's nothing in D3D16 that says you
can have a step or ramp at the
threshold.
So, why is it in the patient care areas
and resident use areas where most
occupants are vulnerable,
why is it you can have a whole 25 mm?
Regardless of why the NCC has permitted
it in the past, these are removed for
NCC 2025. Making level thresholds
necessary for these areas.
A new concession has been introduced for
plant rooms and similar areas.
This makes sense because these areas are
infrequently occupied, space is normally
tight,
and a step is useful in case equipment
leaks.
We've taken the opportunity to make the
provision read better also.
So, look out for these improvements in
NCC 2025.
And also, look out for thresholds like
this one.
Most fire isolated exits I've been in,
there's a door handle on the inside
allowing you to get back onto the floor
you've just left.
For example, this photo is of a building
that the ABCB office was once in.
It has re-entry from the fire stair to
each office level. So, people often use
the stairs instead of the lift.
But for a lot of buildings, it doesn't
have to be this way.
For a lot of buildings, there doesn't
have to be a handle to re-enter the
floor you just left.
The NCC currently doesn't prevent
blocking re-entry from fire isolated
exits except in class 9A healthcare
buildings,
early childhood centers,
class 9C residential care buildings, and
exits serving stories above an effective
height of 25 m.
Only, it's still possible to lock these
off so long as the doors automatically
unlock in fire mode, and a system of
re-entry is provided on every fourth
story.
That's the unlocked door or the intercom
system.
This provision exists partly because of
evacuation needs.
In the large buildings greater than 25
m,
there may be a need to transfer from
stair to stair,
which would be difficult if the exit
you're in doesn't allow re-entry.
And for the class nines listed,
these are situations where assisted
evacuation occurs, which is difficult
without re-entry.
This provision also exists for if people
accidentally enter a fire isolated exit.
It's an inconvenience to travel the
entire exit to get out,
but there's also some building users who
would struggle to find their way out.
So, we've made the list longer.
These are the situations where NCC 2025
requires re-entry from fire isolated
exits.
You still have everything we already
have, but because now all class nines
are included, schools and other assembly
buildings.
That's simply listed as class nine.
What's added now are class two
buildings, so apartment buildings.
Class three,
like hotels,
class six, shopping centers, of course,
and class seven eight car parks.
You can still prevent re-entry for all
or some of these doors, so long as
re-entry is provided in the same way as
it is now, by leaving some unboxed or by
intercom.
Next is a change in the housing
provisions.
For a long time, NCC volume two had a
concession for stairs serving
non-habitable rooms, like attics and
store rooms.
That concession said for these rooms,
you don't have to build normal stairs.
Instead, you could build stairs to AS
1657, which is a standard for stairways,
ladders, and the like for inspection and
maintenance personnel.
Stairs built to AS 1657 won't
necessarily comply with regular stair
provisions because they can be steeper
and their balustrades can have larger
gaps.
This was reviewed in 2015 and that
review saw opportunity to bring
specifications into the NCC itself,
rather than send users to another
standard.
So, we did.
And NCC 2016 had provisions like this
that allow a steeper stair and for
larger gaps in barriers for stairways
serving non-habitable rooms.
Good move, we thought. This meant that
builders didn't have to buy AS 1657 if
they were building a stair for an attic.
However, we found out that the old
concession that referenced AS 1657
was being used for access ladders for
class 10b structures, like radio masts
and communication towers.
And without a concession in the code,
these structures would need normal
stairs or a performance solution.
It made sense for these sorts of
structures to have stairways and ladders
in accordance with AS1657.
That's what the standard was designed
for.
So, we made some changes for NCC 2025.
This new provision allows class 10b
structures to use AS1657.
All the normal stair provisions if you
want.
We've also changed the barrier and
handrail clauses so that you can use
AS1657 for these also.
We think this works better than the
original concession which only mentioned
stairways.
This new provision now mentions ladders,
platforms, and walkways also. So, more
clearly applies to radio masts and
things like that.
These are the main changes to access,
egress, and safe movement. If you have
any questions, please stay for the
question and answer session.